Specifications |
LF 185 |
Measuring standard Coefficient of linear expansion |
SUPRADUR phase grating on steel, grating period 8 µm αtherm 10 x 10–6 K–1 |
Accuracy grade* |
±3 µm; ±2 µm |
Measuring length ML* in mm |
140 240 340 440 540 640 740 840 940 1040 1140 1240 1340 1440 1540 1640 1740 1840 2040 2240 2440 2640 2840 3040 |
Interface |
1 VPP |
Signal period |
4 µm |
Reference marks* LF 185 |
1 reference mark at midpoint; other reference mark positions upon request Distance-coded |
Diagnostics interface |
Analog |
Cutoff frequency –3 dB |
≥ 250 kHz |
Electrical connection |
Separate adapter cable (1 m/3 m/6 m/9 m) connectible to mounting block |
Cable length |
≤ 150 m (with HEIDENHAIN cable) |
Voltage supply |
DC 5 V ±0.25 V/< 150 mA |
Traversing speed |
≤ 60 m/min (max. acceleration in measuring direction ≤ 100 m/s2) |
Required moving force |
≤ 4 N |
Vibration 55 Hz to 2000 Hz Shock 11 ms |
Housing: ≤ 150 m/s2 (EN 60 068-2-6) Scanning unit: ≤ 200 m/s2 (EN 60 068-2-6) ≤ 300 m/s2 (EN 60 068-2-27) |
Operating temperature |
0 °C to 50 °C |
Protection EN 60 529 |
IP53 when installed according to instructions in the brochure IP64 with sealing air via DA 400 |
Mass |
0.8 kg + 4.6 kg/m measuring length |
* Please select when ordering |