Specifications |
LC 195 S |
LC 195 S |
LC 195 F |
LC 195 M |
Measuring standard Coefficient of linear expansion |
DIADUR glass scale with absolute track and incremental track, grating period 20 µm αtherm 8 x 10–6 K–1 |
|||
Accuracy grade* |
±3 µm up to 3040 mm measuring length; ±5 µm |
|||
Measuring length ML* in mm |
140 240 340 440 540 640 740 840 940 1040 1140 1240 1340 1440 1540 1640 1740 1840 2040 2240 2440 2640 2840 3040 3240 3440 3640 3840 4040 4240 |
|||
Functional safety for applications up to |
|
– |
||
PFH |
25 x 10–9; ML > 3040 mm: 40 x 10–9 (up to 1000 m above sea level) |
– |
||
Safe position1) |
Encoder: ±550 μm; ML > 3040 mm: ±2050 µm (safety-related measuring step SM = 220 μm) |
– |
||
|
Mechanical connection: fault exclusions for loosening of the housing and scanning unit (page 21) |
|||
Interface |
DRIVE-CLiQ |
Fanuc Serial Interface/αi interface |
Mitsubishi high speed interface |
|
Ordering designation |
DQ01 |
Fanuc05 |
Mit03-04 |
|
Measuring step At ±3 µm At ±5 µm |
0.001 µm 0.010 µm |
αi interface/α interface 0.00125 µm/0.010 µm 0.0125 µm/0.050 µm |
0.001 µm 0.010 µm |
|
Clock freq. (calc. time tcal) |
– |
|||
Electrical connection |
Separate adapter cable (1 m/3 m/6 m/9 m) connectable on both sides to mounting block |
|||
Cable length |
≤ 30 m2) |
≤ 50 m |
≤ 30 m |
|
Voltage supply |
DC 10 V to 28.8 V |
DC 3.6 V to 14 V |
||
Power consumption (max.) |
10 V: ≤ 1.5 W; 28.8 V: ≤ 1.7 W |
3.6 V: ≤ 1.1 W; 14 V: ≤ 1.3 W |
||
Traversing speed |
≤ 180 m/min (max. acceleration ≤ 100 m/s2) |
|||
Required moving force |
≤ 4 N |
|||
Vibration 55 Hz to 2000 Hz Shock 11 ms |
Housing: ≤ 200 m/s2 (EN 60 068-2-6) Scanning unit: ≤ 200 m/s2 (EN 60 068-2-6) ≤ 300 m/s2 (EN 60 068-2-27) |
|||
Operating temperature |
0 °C to 50 °C |
|||
Protection EN 60 5293) |
IP53 when installed according to instructions in the brochure, IP64 with sealing air from DA 400 |
|||
Mass |
0.55 kg + 2.9 kg/m measuring length |
|||
* Please select when ordering 1) Further tolerances may occur in subsequent electronics after position value comparison (contact manufacturer of subsequent electronics) 2) Larger cable lengths upon request 3) In the application the LC must be protected from the intrusion of particles and liquids |